mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Air Duct > < AR83.10-P-2001R Remove/Install Actuator For Fresh and Recirculated Air Flaps|Page 13854
Page 9
background image

  

1

Remove instrument panel

2

Unscrew screws (2)

3

Disconnect electrical connectors from evaporator housing cover (1)

4

Remove evaporator housing cover (1)

5

Remove right lateral nozzle air flap actuator motor (M16/26) from evaporator housing cover (1)

NOTE:  Installation:  Check condition of adjusting mechanism. If damage is found, obtain appropriate part from kinematics parts kit.

6

Install in the reverse order

7

Read out fault memory

8

Normalize actuator motor.

AH83.10-P-0001-01R Instructions For Installing Actuator Motors

AH83.10-P-0001-01R Instructions For Installing Actuator Motors

The condition of the adjustment mechanism for the corresponding air flap must be checked before mounting the removed actuator motor. If damaged, the
part must be replaced with the corresponding one from the kinematics parts kit and installed.

Component Identification

Air Duct > < AR83.10-P-2001R Remove/Install Actuator For Fresh and Recirculated Air Flaps|Page 13854