SL 550 (230.471) V8-5.5L (273.965) (2008)
Component Identification
GF77.39-P-3019R Side Flap "Folded-In/Out" Limit Switch, Location/Task
GF77.39-P-3019R Side Flap "Folded-In/Out" Limit Switch, Location/Task
- up to model year 08
Component Identification
GF77.39-P-3019-02R Side Flap "Folded-In/Out" Limit Switch
GF77.39-P-3019-02R Side Flap "Folded-In/Out" Limit Switch
- up to model year 08
The left side flap "folded-in/out" limit switch (S126/1) (up to 31.5.07) and right side flap "folded-in/out" limit switch (S127/1) transmit a ground signal
to the RVC control unit (N52) depending on the end positions of the side flaps.
The left side flap "folded-in/out" limit switches (S126/1) (up to 31.5.07) and the right side flap "folded-in/out" limit switch (S127/1) are switched in
series.
If the side flap is not in an end position, a ground signal (open input) is not sent to the RVC control unit (N52).