mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Defroster Vent Flap Actuator Motor|Page 17200 > < Defroster Vent Flap Actuator Motor|Page 17198
Page 12
background image

quickly or to reduce the cooling output demand. Once a time limit of 30 min. has elapsed, recirculation is automatically switched back from 100 % to
maximum 80 %.

Automatic control of the fresh air/recirculated air flap via the AAC multifunction sensor (B31/1)

If the actual pollutant concentration value outside the vehicle as determined by the multifunction sensor (B31/1) is greater than an assumed, mean
interior-air quality, the system will switch to 80 or 100 % recirculated air. As soon as the existing pollutant concentration outside the vehicle once again
lies below the assumed, mean interior air quality, the system is run with fresh air again (exceptions: recirculated air set manually; recirculated air set
automatically because of high ambient temperature).

NOTE:

-

All actuators are identical.

-

The assignment to the flap to be actuated and job description of actuator takes place via a wiring harness coupling.

If a problem exists, it is possible to retrieve and verify the defined end positions by means of the diagnosis system STAR DIAGNOSIS (valuation trip).
An adjustment run must be performed after replacing a actuator motor, in other words the end positions flap OPEN and SHUT are defined and retained.

GF83.30-P-2116R Fresh/Recirculated Air Flap Actuator Motor, Location/Task/Function

GF83.30-P-2116RFresh/recirculated Air Flap Actuator Motor, Location/task/function

Component Identification

GF83.57-P-2105-02R Blending Air Flap Actuator Motor Function

GF83.57-P-2105-02R Blending Air Flap Actuator Motor Function

- with CODE (581) Automatic air conditioning

Defroster Vent Flap Actuator Motor|Page 17200 > < Defroster Vent Flap Actuator Motor|Page 17198