mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

AR83.10-P-2001R Remove/Install Actuator For Fresh and Recirculated Air Flaps|Page 17204 > < Defroster Vent Flap Actuator Motor|Page 17201
Page 1
background image

Air Door Actuator / Motor: Service and Repair
AR83.10-P-2001R Remove/Install Actuator For Fresh and Recirculated Air Flaps

AR83.10-P-2001R Remove/Install Actuator For Fresh and Recirculated Air Flaps

 

1

Remove instrument panel

DANGER:
-

Risk of injury when carrying out test or repair work on airbag or emergency tensioning retractor units

-

Store airbag units with deployment side facing up; do not expose to temperatures greater than 100 degrees C. Interrupt power supply
when working on such units.

2

Disconnect electrical connectors from passenger airbag and remove passenger airbag

3

Disconnect electrical connector (1) from fresh and recirculated air flap actuator motor (M16/21)

4

Remove fresh and recirculated air flap actuator motor (M16/21)

5

Install in the reverse order

6

Read out fault memory.

7

Normalize actuator motor.

AR83.10-P-2001R Remove/Install Actuator For Fresh and Recirculated Air Flaps|Page 17204 > < Defroster Vent Flap Actuator Motor|Page 17201