Air Register: Service and Repair
Related Procedures

AR83.25-P-1404R Remove/Install Right Air Inlet

DANGER:

-

Risk of explosion from gas. Risk of poisoning and caustic burns from swallowing battery electrolyte. Risk of injury from caustic burns to
eyes and skin from battery electrolyte or from handling damaged lead-add batteries

-

No fire, sparks, open flames or smoking.

-

Wear acid-resistant gloves, clothing and eye protection. Pour battery electrolyte only into suitable and appropriately marked containers.

1

Remove battery

NOTE:  Starter battery.

2

Unscrew battery tray (4) and remove

3

Remove water collector

4

Disconnect electric connector (2)

5

Remove dip (5)

6

Unclip clamps (3) and remove air inlet box (1)

NOTE:  Installation:  Do not unclamp water drain valve.

7

Install in the reverse order.