Blower Motor: Description and Operation
GF83.10-P-2103-01R Blower Regulator Function

GF83.10-P-2103-01R Blower Regulator Function

Function

The blower regulator for a manual operation is controlled in 9 stages (control voltage 1.4 - 6.0 V) using the blower switch integrated above the AAC
pushbutton control module (N22) and the A/C databus.
The automatic mode can be selected on the AAC pushbutton control module (N22) using the blower switch's Auto button.
Depending on the actual measured in-car temperature and the selected desired temperature the blower regulator then controls the blower motor operating
voltage of 0 - 12 V. This facilitates blower motor speed control of 0 - 100 %.

Automatic air conditioning (AAC) [KLA]

Automatic Air Conditioning (AAC) [KLA]