Component Identification

Automatic air conditioning, blended air operation with recirculated air
Function

In blended air mode with recirculated air (LED illuminated) interior air is drawn in by the blower motor (A32m1) as a result of the position of the fresh
air/recirculated air actuator motor (M16/21). The air cleaned by the all-purpose filter (2) is led through the cooled evaporator (3), where it is dried and
cooled. After this, part of the dried and cooled air (B) is heated up again in the heated heat exchanger (4) as a result of the position of the left and right
blending air flap actuator motors (M16/28) and (M16/29). The remaining dried and cooled air is diverted past the heating system heat exchanger (4) and
is blended with the heated air (C) to form blended air (D) downstream of the heating system heat exchanger (4).

The position of the left and right footwell flap actuator motors (M16/15) and (M16/16) serves to route the main quantity of blended air (D) to the
footwell vents. The partial quantity of the blended air is blended further with cold air (regulated by the diverter flap actuator motor M16/27) and routed
into the passenger compartment by the center vents and side vents thus achieving a stratification of the interior air (warm feet, cool head).
The defroster vent flaps can be slightly opened by the left and right defroster vent flap actuator motors (M16/13) and (M16/14) if the outside air is dry.
The other flaps can be operated manually. The condensation water is led to the outside condensation water drain.