SL 600 (129.076) V12-6.0L (120.981) (1995)
Ensure that wires/connectors (with locking tabs) are fully inserted into contact carrier and are locked into place.
8.
Insert contact carrier (4, Figure 7) into harness connector (3) and close locking clip.
9.
Connect SRS harness connector (3, Figure 6) to SRS control module (N2/2). If necessary, secure harness connector to SRS control module with
cable tie.
10.
Install SRS control module (N2/2) using allen bolts (2, Figure 8).
Note:
Secure ground wire (5, Figure 8) from SRS harness, with bolt (2), under left side of SRS control module (N2/2)
11.
Secure gray/blue wire from ACSR harness to terminal X6 (Figure 9) circuit 58d.