SL 600 (129.076) V12-6.0L (120.983) (1997)
Power Trunk / Liftgate Lock Actuator: Service and Repair
Remove/Install Trunk Lid Actuator
Cover (1) of right tail lamp
Fold open.
Clips (2)
Pull out.
Cover (3)
Remove.
Retaining catches (4)
Push open.
Actuator (S49)
Disconnect.
Strain relief (5)
Push away.
Electrical cable
Disconnect.
Pneumatic line (6)
Lever off with open-end wrench (width between flats 7).
Actuator (S49)
Check. See: Locks/Power Locks/Power Door Lock Actuator/Testing and Inspection
Actuator
Install in reverse order by inserting actuator carrier (7) into lock carrier (8).