Release catch. Attach multimeter to plug connector (A24x or A25x, pins 1 and 2). Set multimeter to continuity check (acoustic signal). Press catch in
direction "lock" with top wrench (vehicle tool kit). Simultaneously press rotating lock (5) upward with thumb to eliminate play. Limit switch (A24s1
or A25s1) should actuate when the upper edge of the rotating lock (5) is in the switching range (Z). If necessary adjust limit switch (A24s1 or A25s1)
by sliding in oblong holes. Apply screw-securing agent to screws (3) for limit switch (A24s1 or A25s1).

B. On catches without marked switching ranges (X, Y, Z)

Cut paper strips according to drawing and mark as indicated.

X: Main catch
Y: Switching range (2.5 - 3 .5 mm in front of main catch)
Z: Switching range (46 - 48 mm in front of main catch)

Glue paper strips to catch so that upper edge of rotating lock (5) forms a line with the main catch (X) in the locked state (press upward with thumb to
eliminate play).
Continue adjustment as described in A.