Seat Occupant Sensor: Description and Operation
Function

Function Schematic

The front passenger seat occupied recognition sensors (B41) change the resistance when pressure is applied. This is registered and evaluated by the
ETR control module with airbag.

The foil pressure sensors are designed so that a force of 12 kg; over a surface with a diameter of 120 mm is required for actuating the occupied signal.

When the emergency tensioning retractor control module with airbag (AB) recognizes the "seat not occupied" signal the supplemental restraint
equipment (airbag, side airbag and emergency tensioning retractor) on the passenger side are not triggered.