8. Remove drive shaft (11) from the bearing flange (4).

Examine drive shaft (11) and bearing bushes for signs of wear.

9. Use a screwdriver to press radial seal ring (13) out of the bearing flange (4).

34a Vickers/LUK pump
34b ZF pump

10. Remove locking ring (34a or 34b).

CAUTION:  When removing locking ring, ensure that the housing bore is not damaged.

11. Remove flow control valve (32) and compression spring (30) from the pump housing (2).

12. Clamp flow control valve (32) in a vise at the part which is not ground, and unscrew valve screw (53) of the overpressure valve. Remove sealing