SL 600 (129.076) V12-6.0L (120.983) (1997)
-
On models with ASR, using a suitable press tube, push deep-groove ball bearing into place on connecting flange
-
On all models use a new selective locking ring to retain connecting flange to differential side gear
-
Check and adjust connecting flange axial play as follows:
-
Measure axial play between connecting flange (33a) and differential side gear (17)
-
If not to specification of (0.03 to 0.30 mm) choose a new selective lock ring (30a)
-
Lock rings (30a) are available in thicknesses ranging from 1.40 to 2.70 mm in 0.50 mm graduations
-
Clean sealing surfaces for end cover and coat with Hylomar sealer part No. 001 989 25 20, or equivalent
-
Use new collared bolts to retain end cover and tighten to: 50 Nm