Diagnostic Connector - ABS: Technical Service Bulletins
ABS - System Aborts During Diagnostic Procedure

Diagnosis aborts when working on SBC control unit using SDconnect in wireless mode

Topic number

LI42.46-P-048678

Version

1

Design group

42.46 Sensotronic Brake Control (SBC)

Date

01-22-2010

Validity

Model 211, 219 with SBC (up to code 806)
Model 230

Reason for change

Reason for block

Complaint:

When using the SDconnect diagnosis multiplexer in wireless mode (WLAN), diagnosis aborts occur during the SBC bleeding process or in the
subsequent test steps for activating the SBC brake system.

Cause:

Fluctuations in the WLAN signal strength during the SBC bleeding process or in the subsequent test steps for activating the SBC brake system.

Remedy:

Before starting the diagnosis session, connect the SDconnect diagnosis multiplexer to the Star Diagnosis unit using the green Star Diagnosis connecting
cable provided in the package.

This prevents aborts from occurring due to fluctuations in the WLAN signal strength during the diagnosis session.

Plugging in the cable connection during an already active diagnosis session does not prevent the faults from occurring because the change from WLAN
to a cable connection during an active diagnosis session is not recognized.