10

Remove SBC hydraulic unit (A7/3)

NOTE:  Remove SBC hydraulic unit (A7/3) complete with retaining plate.

11

Install in the reverse order

12

Rinse off brake fluid which has run out with water

13

Bleeding brake system with STAR DIAGNOSIS

CAUTION:  The warning buzzer in the instrument cluster is deactivated during the bleeding process. After completing all work,
therefore, the STAR DIAGNOSIS menu item "Activate warning buzzer in instrument cluster" must be called.

AR42.46-P-0011R Remove/Install Pressure Reservoir For (SBC) Hydraulic Unit

AR42.46-P-0011R Remove/Install Pressure Reservoir For (SBC) Hydraulic Unit

- with Sensotronic Brake Control (SBC) [model 211]

Shown On Model 230.475

DANGER:

-

Risk of injury, body parts may become jammed or crushed. Risk of injury, skin and eyes may be injured due to brake fluid spraying out
at high pressure when working on the SBC brake system

-

Deactivate SBC brake system using STAR DIAGNOSIS.

-

Risk of poisoning from swallowing brake fluid. Risk of injury from brake fluid coming into contact with skin and eyes.

-

Pour brake fluid only into suitable and appropriately marked containers. Wear protective clothing and eye protection when handling
brake fluid.

-

Risk of injury when drilling gas-filled assemblies or components (gas filling cannot ignite)

-

Wear safety goggles and face mask

1

Deactivate SBC brake system using STAR DIAGNOSIS.

CAUTION:  See notes on repairs to brake system

2

Remove right Xenon headlamp

3

Unscrew pressure reservoir (1) from hydraulic unit

CAUTION:
-

Before opening the SBC system, thoroughly clean the surrounding area of the separation point. Even the smallest particles of dirt,
introduced into the hydraulic components, can lead to malfunctions and a total failure of the SBC system.

-

Collect any brake fluid which runs out with a fluff-free absorbent cloth in order to avoid damage.

NOTE:
-

In the process counterhold the hydraulic unit by hand.

-

Do not recut the thread in the pressure reservoir or in the hydraulic unit.

-

Installation:  Coat the O-ring of the pressure reservoir with brake fluid.

CAUTION:  See notes on handling brake fluid

4

Install in the reverse order

5

Rinse off spilled brake fluid with water.

6

Activate SBC brake system using STAR DIAGNOSIS.