Page 38
background image

26.

Insert a cable tie through slots (C, Figure 25) in bracket (D), do not close cable tie.

Note:

Cable tie installation is shown on "bolt-on" type mounting bracket, cable tie installation for clamp-on type mounting bracket is similar.

27.

Connect SBC harness connector (A, Figure 27) to SBC hydraulic unit and secure by engaging locking mechanism.

28.

Attach the ground wire harness ring connector (A, Figure 26) to the body ground terminal (B) with M6 nut. Torque the M6 nut to 10 Nm.

Note:

^

The ground wire harness (arrow) must be routed under the SBC suction hose (C). The ring connector (A) must be positioned as shown in

Recall - Inspect/Replace SBC Hydraulic Control Unit|Page 11255 > < Recall - Inspect/Replace SBC Hydraulic Control Unit|Page 11253