mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

P-42_46-43A > < Brakes - Fails STAR(R) Diagnosis Test/Air In System Mssg
Page 2
background image

routine, as instructed below in steps a - b.

a. Using STAR Diagnosis follow the menu path: Control Units -> Chassis   SBC-Sensotronic Brake System -> Actual Values -> Pressures

b. Install one pusher tool (W000 589 52 43 00) in place of each brake lining in the caliper, then slowly operate the brake pedal 5 times to extend

the brake piston up to the pusher tool and then push it back with the pusher tool.

NOTE:  

This procedure is necessary to eliminate any free travel at the sealing ring.

Special Tools

NOTE:  

The following allowable labor operations should be used when submitting a warranty claim for this repair. This information has been generated on
December 19, 2008. Please refer to Netstar -> Star TekInfo -> Star Time for the most current labor time allowance.

In Case of Warranty

Operation: Short test, perform (54-1011)

SBC system - check for air, perform (42-0653)
SBC system - check for air perform (42-0000)
Test program - after short test, perform (54-1012)
Battery charger connect (with SDS connected) (02-5058)
Hydraulic brake system bleed, perform (02-4566)
Hydraulic brake system bleed, perform (02-0000)

P-42_46-43A > < Brakes - Fails STAR(R) Diagnosis Test/Air In System Mssg