19.

Reinstall the SBC wire harness connector cover (A, Figure 13) in reverse order.

Note:

Ensure the locking lugs (arrows) on the harness connector (B) are properly engaged into the harness connector cover (A).

20.

Secure the SBC wiring harness (A, Figure 14) (excluding ground wiring harness) to the SBC connector cover harness receptacle (D) using a new
cable tie (arrow).

Note:

^

Ensure that the SBC wiring harness (A) is properly routed so that it is free of tension in the SBC connector housing.

^

The cable tie "buckle" (C) must be located on the side of the connector cap harness receptacle (D) as depicted.