background image

^

The cable tie "buckle" (D) must be located at the side of the connector cover receptacle (arrow) as depicted.

19.

Secure ground wiring harness (C) to the SBC connector housing receptacle (F) using a new cable tie (E).

20.

Attach SBC harness mounting bracket to the SBC hydraulic unit:

^

Using hand tools, tap threads into SBC hydraulic unit bores (arrows, Figure 21) by running self tapping screw (arrow, Figure 20) into lower
bore without mounting bracket positioned on SBC unit.

Note:

^

In order to avoid breaking the self-tapping screw (arrow) during installation, the screw (arrow) must be positioned absolutely straight

^

Do not use power tools to install self tapping screw.

^

In the event self tapping screw (arrow, Figure 20) is broken during installation of bracket (A) perform step 21 then continue with campaign
(installation of bracket due to breakage of mounting screw will not be covered under warranty).

^

Remove self tapping screw (arrow).

Recall - Inspect/Replace SBC Hydraulic Control Unit|Page 12129 > < Recall - Inspect/Replace SBC Hydraulic Control Unit|Page 12127