mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Recall - Inspect/Replace SBC Hydraulic Control Unit|Page 12133 > < Recall - Inspect/Replace SBC Hydraulic Control Unit|Page 12131
Page 39
background image

Figure 26.

^

This ground terminal (B) is to be used only for mounting the SBC ground wire harness (arrow).

29.

Complete the installation of the SBC hydraulic unit.

30.

Check for leaks and bleed SBC system (refer to WIS: AR42.46-P-0010R), (Refer to SDS instructions).

Note (regarding above WIS instructions):

Disregard WIS notes regarding brake bleeder pressure. The maximum pressure for brake bleeder is 2.5 bar.

31.

Connect SDS and check software release:

Note:

Ensure only the following versions of DAS are used:

^

11/2005 with SBC patch 479 installed on SDS

^

Any DAS version after 11/2005

Navigate through the following menu items in DAS and follow on-screen instructions:

"Control units/Chassis/SBC - Sensotronic Brake Control/Control unit adaptations".

Note:

^

Ensure to follow the on-screen instructions in DAS for connecting programming and terminal inspection tool to the SBC hydraulic unit.

^

In the event of malfunctions during the SBC programming, a message will appear in the DAS display and a troubleshooting guide will be
displayed.

^

In the event DAS indicates that the SBC hydraulic unit requires replacement after inspecting SBC connector terminals, refer to WIS:
AR42.46-P-0010R (for replacement instructions).

Note (regarding above WIS instructions):

Disregard WIS notes regarding brake bleeder pressure. The maximum pressure for brake bleeder is 2.5 bar.

32.

Secure SBC wiring harness (B, Figure 27) to SBC hydraulic unit bracket (C) with cable tie (arrow). Tighten cable tie (arrow) using Hellermann
MK9 cable tie pliers (Special Tool W 352 589 02 37 00); use setting 3 on cable tie pliers.

Note

^

The cable tie buckle (D) must not touch the bracket (C).

^

When attaching SBC wire harness (B) to the bracket (C), ensure that the wire harness (B) touches the bracket (C) and is mounted there
tension free.

^

After the SBC wire harness (B) is secured, it must not be able to move in the longitudinal direction toward the bracket.

CAUTION!

Ensure harness is properly mounted to allow cable strain relief in area between cable tie and connector.

33.

Proceed to SUBJECT C - QUALITY ASSURANCE MEASURES.

C. Quality Assurance Measures

CAUTION!

Check the quality measures outlined below after completing the service procedure.

1.

Quality measure 1:

Recall - Inspect/Replace SBC Hydraulic Control Unit|Page 12133 > < Recall - Inspect/Replace SBC Hydraulic Control Unit|Page 12131