20.

Connect the SBC wire harness connector (D, Figure 20) to the SBC hydraulic unit and secure with connector locking mechanism.

21.

Position ground wiring harness parallel to the vehicle longitudinal axis (X-axis) on the body ground terminal. Torque the M6 nut to 10 Nm.

Note:

^

Ring connector (A, Figure 21) must be positioned as shown to avoid contact with water hose (B) and chafing the wire harness (C).

^

This ground terminal (D) is to be used only for mounting the SBC ground wire.

22.

Connect SDS and check software release: