SL 600 (230.476) V12-5.5L Turbo (275.951) (2004)
1
Remove evaporator housing
2
Push the evaporator housing support (1) out upwards
3
Unclip the clamps (2) and pull sliding clamp (3) out
4
Disconnect the electrical connector (4) from the fresh and recirculated air flap actuator motor
5
Remove tie straps (5) at evaporator housing
6
Fold the right section of the evaporator housing down and separate
7
Disconnect the electrical connector at the right blending air flap actuator motor (M16/29)
8
Remove blending air flap actuator motor (M16/29)
9
Install in the reverse order
10
Read out fault memory.
11
Normalize actuator motor.
AR83.10-P-2004R Remove/Install Actuator For Left Defroster Flap
AR83.10-P-2004R Remove/Install Actuator For Left Defroster Flap
1
Remove instrument panel
2
Unscrew screws (2)
3
Disconnect electrical connectors from evaporator housing cover (1)
4
Remove evaporator housing cover (1)
5
Remove left defroster vent flap actuator motor (M16/13) from evaporator housing cover(1)
NOTE: Installation: Check condition of adjusting mechanism. If damage is found, obtain appropriate part from kinematics parts kit.