mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

GF83.70-P-0006-01R Stationary Heater (STH) Arrangement of Components|Page 16121 > < GF83.70-P-0006-01R Stationary Heater (STH) Arrangement of Components|Page 16119
Page 14
background image

^

"cold" = no flame formation, then the STH control unit or the STH or HB [ZUH] control unit (A6n1) trigger the heater unit fault run-on period
for approx. 120 s with subsequent fault shutoff. The STH fuel metering pump or the STH or HB [ZUH] fuel metering pump (Y23) is switched
off and the control and operating unit (N18, N22 or N22/7) is actuated via CAN-B (CAN-B) with the signal "Blower off".

The control and operating unit (N18, N22 or N22/7) switches the blower motor off and switches from stationary heating mode to normal operating
mode.
At the end of the fault run-on period, the combustion air blower (A6m2) and the circulation pump (A6m1) are switched off. The indicator lamp in the
STH switch (N72s12 or S46) goes out. Malfunction shutoff is present.

For starting up again, the STH heater unit (except model 220) or the STH or HB [ZUH] heater unit (model 220) must be switched off and on again with
the STH switch (N72s12 or S46) after eliminating the cause of the malfunction.

GF83.70-P-3057B Activate Heater Immediately With Radio Remote Control, Function

GF83.70-P-3057B Activate Heater Immediately With Radio Remote Control, Function

- with CODE (228) Stationary heater [models 203 up to 23.4.04, 209.3 up to 31.5.04, 215 as of 1.6.00 up to 31.8.02, 220 as of 1.6.00 up to 31.8.02,
230.4 up to 08]

Component Identification

GF83.70-P-0006-01R Stationary Heater (STH) Arrangement of Components|Page 16121 > < GF83.70-P-0006-01R Stationary Heater (STH) Arrangement of Components|Page 16119