DANGER:

-

Risk of explosion from welding or soldering work on closed air conditioning system. Risk of poisoning from inhaling overheated 
refrigerant vapors. Risk of injury from skin and eye contact with liquid refrigerant.

-

Do not carry out any welding work on the closed air conditioning system or in the surrounding area. No smoking or open flames. Wear
eye protection and protective gloves. Work only in well ventilated areas.

-

Carry out repair work on the air conditioning system circuit only after the system has been discharged.

CAUTION:  Protect air conditioning circuit and components from moisture when carrying out repair work.

1

Discharge air conditioning system

NOTE:  Recycle refrigerant and jot down quantity of compressor oil extracted.

2

Remove instrument panel

3

Remove jacket tube module

4

Drain coolant

5

Remove expansion valve

6

Detach electrical connector (4) for Keyless Go at air duct (2)

7

Remove air duct (2) at evaporator housing

8

Remove tie strap (1) at supporting tube

9

Unclip electrical connector (3) at steering-column tube (8)

10

Remove reinforcement brace (5) at jacket tube (8)
-

Bolt for reinforcement brace of jacket tube to body:  20  N.m

11

Detach electrical connectors (6) of engine group's steering-column adjustment

12

Detach electrical connectors (7) on control module for Active Body Control

13

Detach electrical connector on temperature sensor (B10/6)

14

Unscrew jacket tube (8) and lower
-

Lower bolt, jacket tube to body:  20 N.m

-

Upper bolt, jacket tube to body:  20 N.m

15

Remove insulation mat in front of evaporator housing and unclip fiber optic cable clip

NOTE:  Do not damage fiber optic cable.

16

Remove insulation mat on front passenger side  

17

Detach electrical connectors on front passenger side airbag

18

Detach electrical connector on blower motor (A32m1)

19

Remove nuts (9) on evaporator housing
-

Nut, evaporator housing to crossmember:  8 N.m

20

Dismantle crossmember (10) and remove