mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

GF82.95-P-0001-01R TELE AID, Location Of Components|Page 196 > < GF82.95-P-0001-01R TELE AID, Location Of Components|Page 194
Page 25
background image

The state display in the emergency call system pushbutton switch (EMERGENCY CALL, S93/3) serves as a function check of the EMERGENCY
CALL system.
Every time the EMERGENCY CALL system is switched on the state display comes on for approx. 5 s and signals EMERGENCY CALL readiness.
If an emergency call is triggered, then the state display starts to flash on and off (0.5 s on, 0.5 s off, ...) and the instrument cluster's display shows the
"Call buildup" message (see picture above, text field 1) followed by "Connection active" (see picture above, text field 2). If an emergency call was
unable to be sent, the state display lights up and the instrument cluster's display shows the message "Call buildup failed" (see picture above, text field 3).
If data is sent, the state display adopts the same status as prior to the emergency call being triggered.
If the EMERGENCY CALL system is in diagnostic mode, the state display also starts to flash on and off (1 s on, 1 s off, ...)
An EMERGENCY CALL system error is present when the state display does not go out 5 s after switching on or when it comes on at a later time.

Permanent illumination of the status indicator can have the following causes:
External error

^

Power supply too low

^

Communication with restraint systems control unit (N2/7) interrupted

^

Error on the emergency call system pushbutton switch (S93/3)

^

Error on GPS reception (antenna system)

^

Reception over the EMERGENCY CALL backup antenna (A2/50)

^

Telephone transmitter/receiver D2B (A35/8) or connection to the emergency call system control unit (EMERGENCY CALL, A35/8) faulty

Internal error

^

Fault during authorization procedure

^

Memory fault on the emergency call system control unit (EMERGENCY CALL, A35/8)

^

Rollover sensor faulty

^

GPS reception erroneous

^

No registration when telephone number changed

^

No connection to the telephone transmitter/receiver

The emergency call system control unit (EMERGENCY The CALL, A35/8) can be coded using the handheld tester such that the state display does not
light up despite a lack of authorization (all additional system errors shown despite this).

GF82.95-P-2003R Emergency Call Actuation, Function

GF82.95-P-2003R Emergency Call Actuation, Function

GF82.95-P-0001-01R TELE AID, Location Of Components|Page 196 > < GF82.95-P-0001-01R TELE AID, Location Of Components|Page 194