Convertible Top Control Module: Description and Operation
GF77.39-P-3300-04R Roll Bar/Vario Roof Control Unit, Function

GF77.39-P-3300-04R Roll Bar/Vario Roof Control Unit, Function

- up to model year 08

General

The RVC control unit (N52) controls the vario roof, the roll bar, the rear power windows, the load assist and the remote trunk closing (with code (881)
Remote trunk closing (RTC)). Moreover, the RVC control unit (N52) normalizes the trunk lid.

Discrete inputs:

^

Circuit 30

^

Circuit 31

^

Temperature sensor (A7/5b1)

^

Trunk lid position sensor (B24/16)

^

Hall sensors of left rear power window motor (M10/5)

^

Hall sensors of right rear power window motor (M10/6)

^

Vario roof "locked" limit switch (right rotary tumbler) (S69/2)

^

Vario roof locked limit switch (left rotary tumbler) (S69/3)

^

Vario roof" open/lowered" limit switch (S69/11)

^

Roll bar down/up limit switch (S83/10)

^

Load assist switch (S114)

^

Load assist "up/down" limit switch (S117)

^

Left tubular frame limit switch, locked (S118/1) (up to 31.5.07)

^

Right tubular frame "locked" limit switch (S118/2)

^

Tubular frame "open" limit switch (S119)

^

Trunk lid open limit switch (S124) (without code (881) Remote trunk closing (RTC))

^

Left side flap closed/opened limit switch (S126/1) (up to 31.5.07)

^

Right side flap closed/opened limit switch (S127/1)

Discrete outputs:

^

RVC hydraulic unit (A7/5)

^

RVC valve block (Y55/1)
-

Main valve (Y55/1y1)

-

Roll bar up solenoid valve (Y55/1y2)

-

Close Vario roof solenoid valve (Y55/1y3)

-

Open Vario roof solenoid valve (Y55/1y4)

-

Tubular frame and Vario roof latches solenoid valve (Y55/1y5)

-

Load assist solenoid valve (Y55/1y6)

^

Relay (A7/5k1)

^

RTC relay (A7/5k3) (with code (881) Remote trunk closing (RTC))

^

RTC proportioning valve (A7/5y3) (with code (881) Remote trunk closing (RTC))

^

Left rear power window motor (M10/5)

^

Right rear power window motor (M10/6)

^

Side flaps motor (M49/1)

^

Roll bar (RB) deployment solenoid (Y57/1)

Inputs and outputs via Control Area Network bus, class B (interior compartment) (CAN-B):

The RVC control unit (N52) is connected with other control units via interior CAN-B to exchange information.