Page 7
background image

9.

Remove SBC ground wires (arrows, Figure 9) from SBC harness connector (A):

^

Unpin ground wire connectors (position 37 and 44) using cable release tool and remove from SBC connector housing (A) (special tool nos.: W 000
589 13 99 30 and W 220 589 01 99 50).

^

Discard old ground wiring harness; it is no longer needed.

10.

Insert the new ground wire harness (arrows Figure 9) into the SBC connector housing (A):

^

Insert longer ground wire into position 44.

^

Insert shorter ground wire into position 37.

Note:

Ensure ground wire connectors are properly locked into place.