mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

AR83.10-P-2001R Remove/Install Actuator For Fresh and Recirculated Air Flaps|Page 12685 > < AR83.10-P-2001R Remove/Install Actuator For Fresh and Recirculated Air Flaps|Page 12683
Page 8
background image

AR83.10-P-2017R Remove/Install Actuator For Left Lateral Nozzle Air Flap

1

Remove instrument panel

2

Unscrew screws (2)

3

Disconnect electrical connectors from evaporator housing cover (1)

4

Remove evaporator housing cover (1)

5

Remove left lateral nozzle air flap actuator motor (M16/25) from evaporator housing cover (1)

NOTE:  Installation:  Check condition of adjusting mechanism. If damage is found, obtain appropriate part from kinematics parts kit.

6

Install in the reverse order

7

Read out fault memory

8

Normalize actuator motor.

AR83.10-P-2018R Remove/Install Actuator For Right Lateral Nozzle Air Flap