background image

Check Values For Propeller Shaft Inclination Angle

Memory Screen

The display indicates that the meter is ready to measure angle 5. This angle is no longer measured.

1

Press the MEMORY button once.

The main menu is displayed.

2

Press the MEMORY button again.

The memory displays the measured angle (a, b, d) and the resulting articulation angle 1 (c) and articulation angle 2 (e).

3

Record inclination angle 1 (c) e.g. +0.26 degrees and inclination angle 2 (e) e.g. +0.58 degrees on the data sheet.

4

Press the STEP button.