mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Procedures|Page 12480 > < Auxiliary Battery Relay|Locations|Page 12474
Page 1
background image

Negative: Procedures

AR54.10-P-0003R Disconnect/Connect Ground Cable at Battery

- except CODE (P99) "AMG Black Series" special model

Remove/Install

DANGER:

-

Risk of explosion from hydrogen gas. Risk of poisoning and caustic burns from swallowing battery electrolyte. Risk of injury to eyes and
skin suffering caustic burns from battery electrolyte or from contact with damaged lead acid batteries.

-

No fire, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Pour battery electrolyte only into suitable and
appropriately marked containers.

CAUTION:  Always disconnect the ground line (1) of the on-board electrical system battery (G1) and the starter battery (G1/4), it being
absolutely essential to adhere to the sequence of disconnecting the batteries

1

Switch off all electrical consumers

2

Switch TELE AID to Service mode
-

On vehicles with code (855) TELE AID

NOTE:  As a result the auxiliary battery is not discharged and no emergency call signal is sent, see operator's manual.

3

Disconnect transmitter key from the electronic ignition switch (EIS)

4

Repeatedly press the start-stop button until the ignition is switched off. Remove Keyless Go cards from the vehicle and keep outside the range of
the transmitter.
-

On vehicles with code (889) Keyless go

5

Detach trunk partition

6

Remove trunk floor covering

7

Slacken nut and disconnect ground cable (1) from on-board electrical system battery (G1)

8

Slacken nut and disconnect ground cable (1) from the starter battery (G1/4)

9

Install in the reverse order

NOTE:  All electrical consumers must be switched off.

10

Activating steering angle sensor

11

Calibrate power window

Procedures|Page 12480 > < Auxiliary Battery Relay|Locations|Page 12474