SL 65 AMG (230.479) V12-6.0L Turbo (275.981) (2005)
4.
Plug opening in C-pillar with sealing tape (B-Figure 34). Use 12 x 1.5 mm butyl strip.
5.
Lay sealing tape over sheet metal edge of C-pillar (D-Figure 34). Use 12 x 1.5 mm butyl strip.
6.
Press on C-pillar corner seal.
7.
Fasten surface (A-Figure 34) with glue. Use Loctite 401 (Local Purchase).
8.
Apply sealant to opening in C-pillar corner seal (C-Figure 34). Use MB universal sealant.
From outside between C-pillar corner seal and sheet metal (E-Figure 34).
9.
Completely close Vario roof.
10.
Perform leakage test.