Intercooler, Compressor <--> [Intercooler, Supercharger] > < Recirculating Air Flap Actuator, Compressor <--> [Air Bypass Valve Actuator, Supercharger]|Locations
Page 1
background image

Recirculating Air Flap Actuator, Compressor: Description and Operation

Position

At top part of air cleaner

Task

Operating recirculated air flap steplessly between 0 - 90° for boost pressure control

Design/function

The recirculating air flap actuator is operated by means of a PWM signal supplied by the engine control module.
-

On/Off ratio 100 %

: recirculating air flap closed

-

On/Off ratio 11 - 99 %

: boost pressure control in part load range

-

On/Off ratio 10 %

: recirculating air flap open