Vent Valve, Location/Task/Design/Function|Page 4201 > < Vent Valve, Location/Task/Design/Function|Page 4199
Page 4
background image

Compression spring

Valve housing

Spring cup

Bleed valve

Valve plate

Air admission valve

Connection

76 

Vent valve

Connection to activated charcoal canister

Connection to fuel tank

Fuel tank ventilation

The ventilation valve (4) opens at an overpressure of around 30 to 50 mbar. 
The fuel vapors flow to the activated charcoal canister. 

Fuel tank aeration

The air admission valve (6) opens at a vacuum of around 1 to 16 mbar in the fuel tank. 
Air or fuel vapors are drawn in through the activated charcoal canister.   

Refueling 

The opening pressure of the vent valve (4) of approx. 30 up to 50 mbar is not achieved if the fuel tank cap is removed. The vent line to the activated
charcoal canister remains closed off. This switches off the nozzle more rapidly. 