SLK 230 (170.449) L4-2.3L SC (111.983) (2001)
Convertible Top Position Sensor / Switch: Description and Operation
Vario Roof "Closed" Limit Switch (Right Lug)
Location
In right catch on cross member above windshield
Purpose
To connect ground signal through to combination control module (N10-3) as soon as lug on Vario roof has reached catch in windshield (Vario
roof closed).
Vario Roof "Locked" Limit Switch (Right Rotary Tumbler)
Location
On Vario roof at front right
Purpose
To connect ground signal through to combination control module (N10-3) as soon as right rotary tumbler has locked. The Vario roof "locked"
limit switch (right rotary tumbler) is connected in parallel to the Vario roof "locked" limit switch (left rotary tumbler).
Vario Roof "Locked" Limit Switch (Left Rotary Tumbler)