mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Hot Film Mass Air Flow Sensor, Location/Task/Design/Function|Page 1021 > < Hot Film Mass Air Flow Sensor, Location/Task/Design/Function|Page 1019
Page 4
background image

Schematic representation 
R1, R2 

Fixed resistor 

RH 

Heating resistor 

RL 

Temperature resistor 

RS 

Sensor resistor

The electronics in the hot film mass air flow sensor control the temperature of the heating resistor (RH) by means of a variable voltage so that its
temperature is 160°C above the intake air temperature detected by the temperature resistor (RL). 
The temperature of the thermistor is measured over the sensor resistance (RS).  

Temperature changes which take place as a result of an increased or decreased flow of air regulate the electronics according to the voltage of the
thermistor until the temperature difference of 160°C is again reached. This control voltage is used by the engine control unit as a measure for the metered
air mass. 

The intake air temperature is measured by a further NTC resistance in the hot film mass air flow sensor. 

Hot Film Mass Air Flow Sensor, Location/Task/Design/Function|Page 1021 > < Hot Film Mass Air Flow Sensor, Location/Task/Design/Function|Page 1019