O2 sensor signal upstream of TWC 

Voltage threshold for 

Rich - lean transition 

Lean - rich transition 

Lambda control without correction variable 

Lambda control with correction variable (d), time delay (+TV) in rich direction 

Lambda control with correction variable (e), time delay (-TV) in lean direction

The engine control unit calculates the lambda mean value from the signals supplied by the oxygen sensor downstream of TWC. This value is compared
with a stored value for optimum exhaust emissions. 
If the variation of several measurements is too large, a correction variable (lag time ± TV) is determined for the lambda control. 
Use of the correction factor (value for a new O2 probe about 0) allows one to compensate for aging of the O2 probe upstream of the catalytic converter
within certain limits. If the correction variable exceeds the limit value, the oxygen sensor upstream of the TWC must be replaced.   
In addition, allowance is made for the period of the signal supplied by the sensor upstream of TWC. If no sensor state change takes place, the lambda
control is not active and no two-sensor control is therefore possible either. 

Note: The effect of the three-way catalytic converter is monitored with the oxygen sensor signals downstream of TWC. 