mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

GF82.85-P-0003-01RC Cockpit Management and Data System (COMAND), Location of Components|Page 14987 > < GF82.85-P-0003-01RC Cockpit Management and Data System (COMAND), Location of Components|Page 14985
Page 23
background image

GF82.85-P-2006SKU Switch On/Off Behavior, Function

- with CODE (530) COMAND APS USA (with navigation system)

Activating navigation

The navigation system is activated automatically via the class B (interior) controller area network bus (CAN-B) when the driver door is opened. This
procedure may be accompanied by barely perceptible noise from the DVD-ROM drive that is integrated in the COMAND operating, display and control
unit (A40/3) if the drive contains a Digital Versatile Disk (DVD). The display of the COMAND operating, display and control unit (A40/3) remains
switched off. If no transmitter key (A8/1) status change then occurs (e.g. circuit 15R ON), the navigation system remains active for t = 30 min.

Activation of entire system

All other subsystems are activated when the transmitter key (A8/1) is inserted into the EIS [EZS] control unit (N73) in position 0 (circuit 15C ON).

In position 1 (circuit 15R ON) the display is switched on, provided that the COMAND operating, display and control unit (A40/3) was switched on when
the transmitter key (A8/1) was last removed. The COMAND operating, display and control unit (A40/3) is now operational. The system which was
active before it was last switched off (e.g. radio) is switched on and the corresponding basic menu is displayed. If the COMAND operating, display and
control unit (A40/3) was switched off for longer than t = 30 minutes, a warning menu with notes on the use of the system is displayed.

Conduct when pushing "ON" button

The COMAND operating, display and control unit (A40/3) can also be switched on when the transmitter key (A8/1) is removed by pressing the "ON"
button. All functions are then available for 30 minutes. When 30 minutes has elapsed, the COMAND operating, display and control unit (A40/3)
switches itself off automatically. If the system has switched off after 30 minutes, the system can be switched on again by pressing the "ON" button. The
cycle starts again.

Switch off characteristics

The COMAND operating, display and control unit (A40/3) is switched off when the transmitter key (A8/1) is removed (circuit 15C OFF). The 
navigation system run-on time of t = 30 min starts (standby). All the important locating parameters are stored during the run-on time. The run-on time of
the audio systems is adjustable and is set in the factory when the COMAND operating, display and control unit (A40/3) is being installed. The
COMAND operating, display and control unit (A40/3) is always in "standby" when CAN-B is active.

Pressing the "DISP" button only causes the monitor to switch between the day, night and off modes.

Switch off characteristics at undervoltage

The COMAND operating, display and control unit (A40/3) constantly monitors battery voltage. Depending on the voltage value the system will act as
follows:
If the battery voltage drops below 11.5 V (battery warning limit), a message appears in the display of the COMAND operating, display and control unit
(A40/3) requesting an engine start. If the engine is not started up, yet another warning is issued after 3 minutes have elapsed indicating that only 10 s
remain to switch the engine on before the system is run down. In this case switching on the engine prevents the system from being automatically shut
down. If the system has shut itself off and the voltage rises above 11.5 V again, the COMAND operating, display and control unit (A40/3) does not
switch itself on again automatically.

If a system has been shut down it can still be switched back on again manually. The warning procedure then ensues for as long as the fault is not
eliminated.

Battery voltage below 9.5 V (undervoltage)

The COMAND operating, display and control unit (A40/3) is automatically put into a defined standby condition, in which only the battery voltage
continues to be monitored. In addition to this the current operating status is stored.

The COMAND operating, display and control unit (A40/3) cannot be operated or accessed using STAR DIAGNOSIS when it is in this condition.
Communication with external components does not take place.

GF82.85-P-2006SKV Switch On/Off Behavior, Function

GF82.85-P-2006SKV Switch On/Off Behavior, Function

GF82.85-P-0003-01RC Cockpit Management and Data System (COMAND), Location of Components|Page 14987 > < GF82.85-P-0003-01RC Cockpit Management and Data System (COMAND), Location of Components|Page 14985