mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Ignition Coil|Description and Operation|Page 8232 > < Ignition Coil|Description and Operation
Page 2
background image

The ignition output stages are integrated in the ignition coils.

Function

An output stage is located in each ignition coil for the primary circuit. The ME control unit actuated the ignition coil primary circuit between terminals 2
and 4. The current flow in the primary coil (L1) causes a magnetic field to form. The dwell angle control determines the operating time of the ignition
coil primary circuit and thus the magnetic saturation of the ferrous core of the ignition coil. The primary current flow is interrupted at the moment of 
ignition timing point. The sudden collapse of the magnetic field generates the ignition voltage in the secondary coil (L2) which is fed directly to the spark
plugs.

The voltage supply of the ignition coils is protected at circuit 87 M1

A diode is integrated in each ignition coil for suppressing additional ignition sparks when the output stage is switched off.

Because of the diodes, it is not possible to measure the resistance in the secondary windings. For diagnosis of the ignition coils, the primary current is
measured. The capacitive tap is used to connect measuring equipment.

Ignition Coil|Description and Operation|Page 8232 > < Ignition Coil|Description and Operation