mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

GF07.04-P-6100V O2 Sensors, Component Description|Page 2273 > < GF07.04-P-6100V O2 Sensors, Component Description
Page 2
background image

The balance resistor (6) is dependent on the overall length (L) and on the type of sensor.

While changing the wideband oxygen sensor, the balance resistor is already fitted on the new sensor and must not be changed (resistance depends on the
sensor).

The broadband oxygen sensor is a planar two-cell limit current sensor which as a result of its modular design integrates several functions.

The sensor element consists of a combination of a Nernst concentration cell (sensor cell) and an oxygen pump cell which transports (pumps) the oxygen
ions. The pump action is a purely physical process.

The sensor is able to measure accurately not only at (Lambda) = 1, but also in the lean and in the rich range.

In combination with the control electronics integrated in the ME-SFI control unit, it supplies within a wide lambda range an unequivocal signal within a
wide lambda range (0.7 < (Lambda) < 4.0).

In the case of the oxygen pump cell oxygen ions are "pumped" from the cathode to the anode when an electric voltage is applied to the zirconium dioxide
ceramic.

The oxygen pump cell and the Nernst concentration cell are arranged in such a way as to produce a diffusion gap of about 10 - 50 (Micro)m between
them.

Two porous platinum electrodes, a pump electrode and a Nernst measuring electrode are located within this gap.

The diffusion gap is connected to the exhaust gas by means of a gas inlet hole. The porous diffusion barrier in this case limits the extent to which the
oxygen molecules are able to continue flowing.

As a result of this, provided the pump voltage is sufficient, a limit current is produced which is proportional to the oxygen concentration in the exhaust
gas. The reference electrode of the Nernst concentration cell is exposed to the ambient air by means of an opening in the reference air passage. The
components of the exhaust gas diffuse through the diffusion gap to the electrodes of the oxygen pump cell and of the Nernst concentration cell where
they are brought into a thermodynamic equilibrium.

GF07.04-P-6100V O2 Sensors, Component Description|Page 2273 > < GF07.04-P-6100V O2 Sensors, Component Description