Temperature Sensor (Gauge): Component Tests and General Diagnostics

Magnetic Type

1.

Turn ignition switch to On or ACC position.

2.

Connect a 10 ohm resistor between gauge lead and ground. The centerline of pointer should fall within the band around the H mark.

3.

Connect a 73 ohm resistor between gauge lead and ground. The centerline of pointer should fall within the band around the C mark.

4.

If gauge tests within calibration, replace sender.

5.

If gauge is out of calibration, replace gauge.

Bimetal Type

    The instrument voltage regulator (IVR) supplies a common regulated voltage for temperature, oil pressure and fuel gauges. The IVR is malfunctioning
only if all gauges show similar problems.
    Test temperature gauge with Rotunda Gauge Tester 021-00055 or equivalent or with a 10 ohm resistor for high calibration and a 75 ohm resistor for
low calibration as follows:

1.

Turn ignition switch to On or ACC position.

2.

Connect a 10 ohm resistor between gauge lead and ground. The centerline of pointer should fall within the band around the H mark.

3.

Connect a 75 ohm resistor between gauge lead and ground. The centerline of pointer should fall within the band around the C mark.

4.

If gauge tests within calibration, replace sender.

5.

If gauge is out of calibration, replace IVR and retest.

6.

If gauge is out of calibration, replace gauge.

Refer to DIAGNOSTIC CHARTS for coolant temperature indicating system diagnosis.

Temperature Switch (Warning Indicator) > < Pinpoint Tests|Page 1864