Accelerator Pump: Description and Operation

Fig. 7 Accelerating pump lever adjustment

    Fig. 7--With throttle plates in the wide  open position, and pump arm manually  depressed, insert a feeler gauge of the  specified thickness between
operating  lever adjustment screw head and pump  arm. Adjust clearance as necessary by  loosening the lock screw, then turning the  adjusting nut while
holding the screw. Turn  the adjusting nut in to increase clearance  or out to decrease clearance. When proper  clearance is obtained, hold nut and tighten
 screw. Note that 1/2 turn of the adjusting nut  is equal to approximately .015 inch. 