mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Load Test|Page 6172 > < Load Test|Page 6170
Page 1
background image

Alternator: Testing and Inspection
On-Vehicle Test

CAUTION

-

Do not make jumper wire connections except as directed. To do so may damage Generator (GEN).

-

Do not allow any metal object to come in contact with the housing and internal diode cooling fins with key on or off or short circuit will result and
burn out the diodes.

NOTE

-

Battery terminals and cable clamps must be clean and tight for accurate meter indications.

-

Proceed to the Starter, Alternator, Battery, Regulator Tester (SABRE) procedure manual for complete directions on checking out the charging
system.

Diagnosis is required before actual repair can be made to the electrical system. Even where an obvious condition makes installation of a new component
necessary, find out why the component failed. When a condition is diagnosed correctly, unnecessary repair is prevented, the vehicle down time will be
decreased, and the condition will be corrected the first time.

The use of SABRE tester is suggested to check the charging system.

Turn OFF all lamps and electrical components when performing charging system tests. Place transmission in NEUTRAL and apply the parking brake.

Load Test

1. Switch the SABRE in the voltmeter function.
2. Connect the voltmeter positive lead to the generator B+ terminal and the negative lead to ground.
3. Turn all electrical accessories OFF.
4. With the engine running at 2000 rpm, check the generator output voltage. The voltage should be between 13.0 and 15.0 volts. If not refer to the

Symptom Chart for diagnostic procedures.  See: Testing and Inspection/Symptom Related Diagnostic Procedures

Load Test|Page 6172 > < Load Test|Page 6170