6. Disconnect the radiator coolant expansion tank hose and wiring harness.

-

Disconnect the coolant expansion tank breather hose bracket from the stud on the left-hand valve cover.

-

Disconnect the wiring harness from the lefthand valve cover.

7. NOTE:  Remove the bolts in the indicated sequence.

Remove the valve cover and discard the gasket.

Installation

1. Prior to installation, clean the valve cover sealing surfaces using a shop towel and metal surface cleaner.

2. NOTE:  Use a new gasket in the valve cover and install the valve cover within six minutes of applying the sealant. Before installing the valve

cover, apply a drop of sealant approximately 8 mm in diameter to the joint areas shown in the diagram. 

Position a new gasket on the valve cover.
-

Apply silicon gasket and sealant where indicated.

3. Tighten the valve cover bolts in the indicated sequence.

Valve Cover|LH|Page 2724 > < Valve Cover|LH