mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Powertrain Management > < Exhaust System|Service and Repair
Page 2
background image

Installation

CAUTION:  The hanger insulators are constructed of a special material. Use only the correct specification insulators.

NOTE:  Check the hanger insulators for damage or fatigue. Install new insulators if required.

1. To install, reverse the removal procedure.

-

Lubricate the exhaust hanger insulators with Myrpol Lubricant D7AZ-19553-AA or equivalent meeting Ford specification ESE-M99B144-B.

Powertrain Management > < Exhaust System|Service and Repair