13. Separate the blower housing lower halves.

-

Release the two retaining tabs.

14. Disassemble the blower upper housing.

1. Detach the seal.
2. Release the three retaining tabs.

15. Separate the housing.

1. Release the five retaining tabs.
2. Pull off the clip.

16. Disassemble the housing.

1. Pull out the air door control shafts (two shown).
2. Remove the three air doors.

ASSEMBLY

NOTE:  Secure the housing halves with additional clips as the retaining tabs can be damaged when the housing halves are disconnected.