mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Refrigerant|Service and Repair > < Environmental Impact Information|Page 7045
Page 1
background image

Refrigerant: Vehicle Damage Warnings

CAUTION:

-

The A/C refrigerant Analyzer must be used before the recovery of any vehicle's A/C refrigerant. Failure to do so puts shop bulk refrigerant at risk
of contamination. If the vehicle A/C refrigerant is contaminated, refer the customer to return to the repair facility that performed the last A/C
repair. If the customer wishes to pay the additional cost, use the A/C recovery equipment that is designated for recovering contaminated A/C
refrigerant. All contaminated A/C refrigerant must be disposed of as hazardous waste. For all equipment, follow the equipment manufacturers
procedures and instructions.

-

The refrigerant identifier must be used before the system is evacuated, otherwise the service station may become contaminated. Contaminated
refrigerant must be disposed of as special waste. The manufacturer's instructions must be followed when dealing with the service station.

-

The air conditioning system must always be evacuated before filling.

-

Only gaseous filling of the air conditioning system is carried out through the low-pressure connection.

-

The maximum pressure of 13.5 bar must not be exceeded.

Refrigerant|Service and Repair > < Environmental Impact Information|Page 7045