mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Refrigerant Discharging and Recovery Procedure|Page 2430 > < Refrigerant Discharging and Recovery Procedure|Page 2428
Page 2
background image

-

Open the high-pressure side shut-off valve on the gauge set.

-

Switch the service unit to "Fill" mode and fill with the prescribed quantity of liquid refrigerant (R-134a).

6. Filling the air conditioning system through the low-pressure connection.

-

Open the low-pressure side shut-off valve on the gauge set.

-

Switch the service unit to "Fill" mode and fill with gaseous refrigerant.

-

Add the remaining amount of refrigerant with the air conditioning switched on. To do so run the engine at about 1200-1500 rev/min. Set the
air conditioning system to full cooling power and fresh air mode. Set the blower to full power. Fill with the remainder of the prescribed fill
quantity.

CAUTION:  Only gaseous filling of the air conditioning system is carried out through the low-pressure connection.

7. Disconnect the servicing unit.

-

Close the shut-off valve.

-

Switch off the servicing unit.

-

Separate the refrigerant hoses from the air conditioning system.

-

Screw protective caps on the fill valves.

NOTE:  Do not detach the high-pressure hose when the air conditioning is switched on.

Refrigerant Discharging and Recovery Procedure|Page 2430 > < Refrigerant Discharging and Recovery Procedure|Page 2428