mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Refrigerant Pressure Sensor / Switch, HVAC|Service and Repair > < A/C Cycling Switch
Page 1
background image

Refrigerant Pressure Sensor / Switch: Description and Operation
Air Conditioning High Pressure Switch

Location

In the line from the compressor to the condenser.

Function

Protection of the air conditioning system against a pressure overload by cutting out the compressor.

Operation

The function of the high pressure switch is to protect the high pressure section of the refrigerant circuit. When pressure exceeds the maximum value of
2965 kPa (430 psi) because, for instance, the air flow through the condenser is impeded or the high-pressure line is blocked, the high pressure switch
switches the compressor off.

Only when the pressure has fallen once more to 2241 kPa (325 psi)  bar is the compressor switched on again. At a pressure level of 2241 kPa (325
psi)
 the PCM switches to high fan speed.

Only when the pressure has fallen once more to 1717 kPa (249 psi) does the PCM switch to low fan speed.