Air Register: Description and Operation

Air distribution is controlled by four instrument panel A/C registers.

^

Retaining holes located on the sides of the A/C register louver assemblies lock the louver assemblies to pivot pins in the A/C housing trim panel
register.

^

The louver assembly pivots and directs A/C register outlet air up and down while louvers permit side-to-side air distribution.

^

A knob located at the side of the louver assembly controls an A/C register air outlet shut-off door installed in the rear of the instrument panel trim
panel A/C register housing opening.

^

The holes lock the louver assembly to pivot pins in the A/C register housing.

^

The housing has four flexible tabs (two on top and two on the bottom) that lock the housing into the instrument panel A/C register assembly
opening.