Condenser Fan Motor Relay: Service and Repair

REMOVAL

1. Remove radiator upper sight shield (8C291).
2. Disconnect electrical connector to constant control relay module.
3. Remove CCRM retainer bracket bolt located on radiator support (16138) and remove constant control relay module.

INSTALLATION

1. Follow removal procedure in reverse order.
2. Tighten constant control relay module bracket retainer bolt to 2-3 Nm (12-18 in. lbs.).
3. Tighten electrical connector bolt securely.